hiclover incinerator control case

31 Dec
2019
It features unique and advanced merits with compact size, high burning effect, reasonable burning technology, high degree of non-harm etc.It is an ideal choice for waste treatment of hospitals, hotels and various areas.

Features:

(1)   Gasifiedpyrolysis incineration is used for burning many kinds of waste.
(2)   Waste can be burned once everyday by gasified incineration.
(3)   Gasified incineration, mixed incineration and burnout treatment ensures low emission standard of dust,dioxin etc.
(4)   Totally enclosed operation is suitable for treating infectious waste to avoid secondary pollution.

(5)   Compact structure and small land occupation.

WWW.HICLOVER.COMWaste Incinerators Auto Roll Air Filters
Nanjing Clover Medical Technology Co.,Ltd.

Tel:  +86-25-8461 0201   

Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
The Incinerator Packages shall be designed to burn non-hazardous solid wastes such as wood, paper, 
cardboard, and food
waste from the West Qurna I field, as well as liquid wastes fed thru the dedicated liquid waste 
burning equipment.
Non restricted solid waste shall be fed to the incinerator by means of a hydraulic ram feeding 
mechanism. The hydraulic ram feeder
shall allow the continuous feeding of the waste without having to open the incinerator while 
it is being fired. The combustion gases shall
be vented to atmosphere at safe location by means of an exhaust stack. The ash produced 
during the incineration cycle shall be
automatically and continuously removed for disposal. Fuel gas shall be used as the primary 
fuel for the incinerator, with the burners
being dual fuel capable using diesel.

Primary Chamber
Primary Combustion Air Fan
Dual Fuel Ignition Burners – Fuel Gas Primary / Diesel Secondary (design to fire sour 

gas with H2S concentration of 1500 ppm)
Incinerator Burners shall be designed for low NOx emissions to meet requirements 
of Note19 on sheet 3.
Bidders shall describe their burner control system in their proposal
Secondary Chamber
Secondary Combustion Air Fan
Exhaust Stack (fitted with sample ports for use with portable emissions monitoring equipment supplied by others)
Liquid Waste Burning Equipment (tank, pumps, agitators, filters, level controls, etc) (for both Incinerators)
Automatic Continuous Ash Removal Equipment
Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800–1000 800–1000 800–1000 800–1000 800–1000
2nd. Chamber Temperature 1000-1200 1000-1200 1000-1200 1000-1200 1000-1200
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm